Home Subscription Services
 
   

 
Quintessence International
QI Home Page
QI Pre-Print
About the Editor
Editorial Board
Accepted Manuscripts
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: QI
Quintessence International

Edited by Eli Eliav

ISSN 0033-6572 (print) • ISSN 1936-7163 (online)

Publication:
April 2016
Volume 47 , Issue 4

Back
Share Abstract:

A retrospective multicenter case series evaluating a novel 3.0-mm expanding tapered body implant for the rehabilitation of missing incisors

Scott MacLean, DDS, FADI, FPFA, FACD / Marc Hermans, DDS / Luke Villata, BDS, MS, MRACDS / Giovanni Polizzi, MD, DDS / Nikhil Sisodia, BDS / James E. Cherry, DMD

Pages: 297–306
PMID: 26949759
DOI: 10.3290/j.qi.a35626

Objective: Narrow-diameter implants are indicated for narrow sites, small interdental/interimplant spaces, or sites with congenitally missing teeth. They also offer a substitute for invasive augmentation procedures. The authors retrospectively evaluated the performance of a new 3.0-mm diameter implant for rehabilitating small anterior spaces. Method and Materials: This observational multicenter retrospective case series included consecutive patients needing single-unit restoration for mandibular and lateral maxillary incisors. The outcome variables were: implant survival, Plaque Index, pocket probing depth (PPD), Jemt’s papilla index, bleeding on probing (BOP), and marginal bone remodeling. Results: In total, 45 patients received 58 3.0-mm implants placed in healed sites (n = 22), extraction sockets (n = 16), or sites with congenitally missing teeth (n = 20). Average follow-up time was 15.1 ± 5.2 months. Prosthetic loading was immediate (n = 23), early (n = 16), or delayed (n = 19). Two implants were lost, and two prosthetic complications occurred. One-year bone remodeling averaged −0.36 ± 0.85 mm (n = 44). PPD averaged 1.75 ± 0.58 mm. Neither BOP nor plaque was detected around implants. Conclusions: At 1-year follow-up, narrow 3.0-mm diameter implants placed in mandibular and lateral maxillary incisor sites demonstrate a high survival rate and support stable marginal bone levels and healthy soft tissue.

Full Text PDF File | Order Article

 

Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.
  © 2021 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog