Early Loading of Titanium Dental Implants with an Intraoperatively Conditioned Hydrophilic Implant Surface: 3-Year Results of a Prospective Case Series Study
Stefan Paul Hicklin, Dr Med Dent/Simone F. M. Janner, PD Dr Med Dent/Nicole Schnider, Dr Med Dent/Vivianne Chappuis, DDS, Prof Dr Med Dent/Daniel Buser, DDS, Prof Dr Med Dent/Urs Brägger, Prof Dr Med Dent
PMID: 32991653
DOI: 10.11607/jomi.8045
Purpose: The hydrophilic implant surface (INICELL) is a chemical alteration of a sandblasted and thermally acid-etched surface that should lead to long-term osseointegration. This study investigated 3-year results after early loading of implants with a hydrophilic, moderately rough surface in occlusal contact. Materials and Methods: This prospective case series study was conducted in subjects with partially edentulous mandibles. Implants were placed on day 21 and loaded with a provisional reconstruction after at least 21 days of healing (baseline, day 0) if their implant stability quotient (ISQ) was ≥ 70 (mean of three measurements) and were replaced by definitive porcelain-fused-to-metal prostheses at the 6-month follow-up visit. Follow-up examinations were planned 1, 3, 6, 12, and 36 months after baseline. Results: A total of 20 implants were placed in 15 patients (mean age: 51 years, range: 32 to 67 years). After 36 months, all implants were osseointegrated, and no suppuration was recorded. Small changes of bone level were observed between 3 months and 36 months. At 36 months, the median values of the 20 implants were 0.25 (range: 0 to 0.5, SD: 0.17), 0.25 (range: 0 to 1, SD: 0.27), and 4 (range: 2 to 7.25, SD: 1.17) for the mean modified Plaque Index (mPI), mean modified Sulcus Bleeding Index (mSBI), and mean probing pocket depth, respectively. The pairwise analysis between 3 and 36 months showed an improvement in the mean mPI (P = .0126) and mean mSBI (P = .0059). After 36 months, all patients (n = 15) were fully satisfied with a mean of 9.43 (range: 8 to 10, SD: 0.678) at the visual analog scale. Conclusion: Early functional loading of implants with a hydrophilic, moderately rough outer surface in occlusal contact 21 days after healing appears to be a safe and feasible treatment option when placed in the posterior mandible of partially edentulous patients.
© 2022 Quintessence Publishing Co, Inc |
JOMI Home Current Issue Ahead of Print Archive Author Guidelines About |
Accepted Manuscripts Submission Form Submit Reprints Permission Advertising |
Quintessence Home Terms of Use Privacy Policy About Us Contact Us Help |