LOGIN
 
Share Page:
Back

Volume 34 , Issue 4
July/August 2019

Pages 891898


Effect of Multiple Use of Impression Copings and Scanbodies on Implant Cast Accuracy

Jordan Sawyers, BDentSc, BSc (Hons)/Mirza Rustum Baig, MDS, FDSRCSEd, FDRCPS, MRD, MFDS, GCHE/Bilal ElMasoud, DClin Dent, FRACDS


PMID: 31107939
DOI: 10.11607/jomi.6945

Purpose: There are currently no clear guidelines on the reuse of metal implant impression copings and scanbodies in implant dentistry. Manufacturers generally recommend single use, which has cost and ecologic implications. The objectives of this study were to examine the effect of multiple use of implant impression copings and scanbodies on the accuracy of partially dentate implant casts. Materials and Methods: Ten direct polyether impressions were made of a partially dentate mandibular acrylic resin master model fitted with two internal connection implants (Straumann RC bone level) in the positions of right first premolar and molar, to produce 10 dental stone casts. A single set of impression copings was utilized for the 10 impressions. The sample casts and the master model were digitized using a laboratory scanner. Ten digital scans were then performed on an implant stone cast with two bone-level internal connection implant analogs using one set of scanbodies to produce scans 1 to 10. Measurements were made on all the digitized casts using computer software and discrepancies calculated in the x-, y-, and z-axes, and in the overall three-dimensional position (R). Data were statistically analyzed using paired t tests (α = .05), and P values were adjusted using Holm- Bonferroni sequential correction. Results: The outcomes were mixed, in that no significant differences were found between the casts or scans produced by reusing impression copings (P > .05) and scanbodies (P > .005), respectively, in all dimensions, for most repetition cycles; however, significant differences were noted in the y-axis for cast 6, and in relation to R, for casts 2, 4 (P < .05), and 8 (P < .005), and the scanbody reuse elicited significant differences in 3D(R) with scan 2 alone (P < .005). Conclusion: Reuse of impression copings and scanbodies up to 10 times did not seem to consistently affect the accuracy of partially dentate multi-implant dental casts and digital models.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help