LOGIN
 
Share Page:
Back

Volume 34 , Issue 3
May/June 2019

Pages e21e31


Use of Patient-Specific Finite Element Models in Dental Rehabilitation to Investigate Stresses of a Fibula Free Flap for Mandibular Reconstruction


Kylan Walsh/Chester Jar/Behzad Vafaeian, PhD/Johan Wolfaardt, BDS, MDent (Prosthodontics), PhD/Daniel Aalto, PhD/Samer Adeeb, PhD


PMID: 30892284
DOI: 10.11607/jomi.6608

Purpose: This study investigated the effect of implant length, diameter, and surface contact on the stresses developed in a fibular free flap. Materials and Methods: Finite element models for dental implants placed in a patient-specific fibula were created using a patient-specific fibula computed tomography scan and geometry files of commercially available dental implants. The finite element models involved nine dental implants of different lengths and diameters: 3.5, 4.3, and 5.0 mm in diameter and 10.0, 11.5, and 13.0 mm in length. Three contact conditions between the implant and the fibular flap were investigated: complete fusion, friction, and smooth contact, representing complete osseointegration, a rough implant-bone interface, and no osseointegration, respectively. Finite element analysis was performed to examine the average von Mises stresses around the local implant-fibula interface within the fibula under a load of 500 N along the long axis of the implant and posterior-anterior and medial-lateral directions. Results: Both the level of osseointegration and implant size had noticeable effects on the mechanical stress inside the fibula. The stress introduced to the fibula gradually decreased as the implant osseointegrated into the bone. An optimal implant size existed where the internal stresses were minimized; this trend was seen when investigating both the implant diameter and length. In this study, an implant with a diameter of 4.3 mm and length of 10 mm produced the lowest mechanical stresses overall. Conclusion: Both implant length and diameter were influential; stresses were seen to decrease to a minimum then subsequently increase as either dimension increased. Additionally, stresses in bone introduced by an implant decreased as the degree of interaction between the implant and fibula increased. Complete fusion between the implant and bone yielded the lowest stresses.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help