LOGIN
 
Share Page:
Back

Volume 34 , Issue 1
January/February 2019

Pages 169–178


Immediate Loading of Two Unsplinted Implants in Edentulous Patients with Mandibular Overdentures: A 10-year Retrospective Review of Patients from a Previously Conducted 1-year Cohort Study

Christophe Rignon-Bret, DDS, PhD/Claudine Wulfman, DDS, PhD/Alain Hadida, DDS, PhD/Franck Renouard, DDS/Pierre-Antoine Gourraud, PhD, MPH/Adrien Naveau, DDS, PhD


PMID: 30695092
DOI: 10.11607/jomi.6931

Purpose: This 10-year retrospective study aimed to report implant bone changes in completely edentulous patients after a mandibular immediate loading protocol using two ball attachments. Materials and Methods: This study was initially designed as a prospective 1-year cohort study, then extended with a 10-year retrospective evaluation of implant bone change. In the first part of the study, 43 edentulous patients wearing satisfactory maxillary and mandibular dentures for at least 3 months were included. Two interforaminal implants (Brånemark system, Nobel Biocare) were placed symmetrically in the anterior mandible using a surgical template and a torque greater than 40 Ncm. Immediately following surgery, 2.25-mm-diameter ball abutments were screwed to the implants, and their matrices (Dalbo Plus, Cendres et Métaux) were incorporated in the denture base. In an initial 1-year study, clinical recalls were scheduled 3, 6, and 12 months after implant placement with a team of two investigators. The follow-up consisted of a clinical examination and a standardized radiographic assessment of the vertical bone change. Implant stability was then monitored. The patient satisfaction was evaluated with a questionnaire before and 3 months after loading. The second part of the study occurred 10 years after the inclusion, as patients were recalled for an implant bone change monitoring. Results: The included patients were 28 to 80 years of age (mean: 61 ± 11.4 years). Three out of 86 implants failed during the healing phase (survival rate of 96.5% [90.1%, 99.2%]). Implant stability was maintained all along the 1-year follow-up (Δ = 73.33, 95% CI [72.39 to 74.26], P = .032). The mean radiographic bone loss was 0.27 ± 0.35 mm at 3 months after surgery, 0.47 ± 0.42 mm after 1 year, and 0.95 ± 0.98 mm after 10 years. General visual analog scale satisfaction was increased by 25 units with the treatment. No patients were lost to follow-up at 1 year, but five were lost at 10 years. Conclusion: This protocol of immediate loading of two unsplinted mandibular implants in overdenture patients using ball attachments is a clinically viable treatment with a high implant success rate and improved satisfaction.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help