LOGIN
 
Share Page:
Back

Volume 34 , Issue 1
January/February 2019

Pages 150–158


Three-Year Prospective Randomized Comparative Assessment of Anterior Maxillary Single Implants with Different Abutment Interfaces

Lyndon F. Cooper, DDS, PhD/Glenn Reside, DDS/Clark Stanford, DDS, PhD/Chris Barwacz, DDS, PhD/Jocelyne Feine, DDS, PhD/Samer Abi Nader, DDS, PhD/Todd Scheyer, DDS, MS/Michael McGuire, DDS


PMID: 30695089
DOI: 10.11607/jomi.6810

Purpose: The goal of this investigation was to define time-dependent peri-implant tissue changes at implants with different abutment interface designs. Materials and Methods: Participants requiring replacement of single maxillary anterior and first premolar teeth were recruited and treated under an institutional review board (IRB)-approved protocol. Implants, titanium abutments, and provisional crowns were placed in healed ridges 5 months following preservation after tooth extraction with recombinant human bone morphogenetic protein-2 (rhBMP-2). Twelve weeks later, permanent crowns were placed on patient-specific abutments and evaluated at 6, 12, and 36 months following implant placement. Clinical and radiographic assessments of abutments and crowns, peri-implant mucosa, and marginal bone levels were recorded. Results: The 3-year assessment included 45 conical interface (CI), 34 flat-to-flat interface (FI), and 32 platform-switched interface (PS) implants in 111 participants. At 3 years, the mean marginal bone level (MBL) change at CI, FI, and PS implants was –0.12, –1.02, and –1.04 mm, respectively (P = .014). “Zero” MBL loss or gain was measured over the 3-year period at 72.1% CI, 3.0% FI, and 16.6% PS implants. There was a minor change (0.0 to 0.3 mm) in peri-implant mucosal zenith positions over time and between groups. Eighty percent of CI implants, 61% of FI implants, and 84% of PS implants were observed to have a clinically stable peri-implant mucosal zenith position with less than 0.5 mm of measured recession. Over the 36-month period, there were no significant changes in the location of mesial or distal papilla in any group. Conclusion: Significant differences in MBLs were observed at different implant interfaces. Conical implant interfaces, but not flat-to-flat or platform-switched implant interfaces, were associated with no MBL changes over 3 years. Peri-implant mucosal stability was generally observed. The relationship of marginal bone responses and peri-implant mucosal stability requires further evaluation.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help