Resonance Frequency Analysis: Agreement and Correlation of Implant Stability Quotients Between Three Commercially Available Instruments

Michael R. Norton, BDS FDS RCS(Ed)


PMID: 30282089
DOI: 10.11607/jomi.6964

Purpose: The purpose of this study was to analyze the implant stability quotient (ISQ) values recorded by three commercially available resonance frequency analysis (RFA) instruments from a large cohort of implants in order to determine their accuracy and agreement with one another both for static measurements of ISQ at a given time and for change in ISQ over time. Materials and Methods: A cohort of n = 210 implants had their primary stability, secondary stability, or both evaluated in both the mesiodistal (MD) and buccolingual (BL) directions by means of ISQ using three different RFA instruments: Osstell ISQ (OISQ), Osstell IDx (OIDX), and the Penguin (PG). ISQ values were recorded both at the time of implant placement and at 3 months postinsertion prior to definitive restoration. All values were tabulated for a blinded statistical analysis using Bland-Altman plots to determine if the outcome values were in agreement both for primary and secondary stability. In addition, a subgroup was evaluated to determine if change in ISQ was also in agreement. An intraclass correlation (ICC) was used to measure the reliability of the measurements for each instrument. Results: Bland-Altman plots confirmed that there was a high agreement for MD values between OISQ and OIDX, with 72.7% of readings being within one ISQ unit and 94.7% within four units. Comparing PG to OISQ, the respective values at one and four units were 15.3% and 82.3%, and comparing PG to OIDX, the respective values were 16.3% and 85.2%. In general, there was a greater uncertainty in the BL values having wider variability and demonstrating less agreement between instruments, with the percentage of readings falling within four units reducing to 85.9% (OISQ vs OIDX), 72.3% (PG vs OISQ), and 74.3% (PG vs OIDX). For change in ISQ over time, 92.3% of values were in agreement to within four units between instruments OISQ and OIDX in the MD direction and 73% in the BL direction. The respective percentage changes of values in agreement within four units for PG vs OISQ were 76.9% and 60.3% and for PG vs OIDX were 80% and 53.8%. The paired t test from mixed effects revealed that there was a significant difference for mean MD values between PG vs OISQ; P = .015 with a mean 0.823 units higher was recorded for PG. Similarly for PG vs OIDX, P = .008 with a mean 0.871 units higher was recorded for PG. For mean BL values between PG vs OIDX, P = .000 with a mean 1.161 units higher was recorded for PG, and finally, for OISQ vs OIDX, P = .005 with a mean 0.597 units higher was recorded for OISQ. However, the maximum upper and lower bound estimated bias between any two instruments was only 1.86 units and 0.46 units both for PG vs OIDX in the BL direction, and it is doubtful that this is of clinical relevance even if statistically significant. ICC revealed that for static MD measurements, there was an 85% reliability between all three instruments (range: 79% to 97%). For BL measurements, the reliability value was 66% (range: 69% to 71%). When considering ICC for changes in ISQ values over time in the MD direction, there was a 70% reliability between all three instruments (range: 58% to 94%). For BL measurements, the reliability value was 58% (range: 46% to 91%). Conclusion: Differences exist between instruments to some extent, most notably between the Penguin and the two instruments from Osstell, which showed good agreement to each other. While differences in evaluating ISQ with the PG were statistically significant, they were less than 1.86 units at the upper bound limit, and it is doubtful that this is of clinical relevance. Increased variability and reduced reliability for BL values render these less clinically sound when trying to assess primary stability.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help