LOGIN
 
Share Page:
Back

Volume 33 , Issue 4
July/August 2018

Pages 888–894


Bone Volume Dynamics and Implant Placement Torque in Horizontal Bone Defects Reconstructed with Autologous or Xenogeneic Block Bone: A Randomized, Controlled, Split-Mouth, Prospective Clinical Trial

Rafael Guimarăes Lima, DDS, MS/Tito Guimarăes Lima, DDS, MS/Carlos Eduardo Francischone, DDS, MS, PhD/Cecilia Turssi, DDS, MS, PhD/Neuza Maria Souza Picorelli Assis, DDS, MS, PhD/Bruno Salles Sotto-Maior, DDS, MS, PhD


PMID: 30025006
DOI: 10.11607/jomi.6288

Purpose: The aim of this study was to evaluate volumetric stability of autologous and xenogeneic block grafts and primary stability of implants in maxillary grafted areas. Materials and Methods: Each patient received one autologous block and xenogeneic block, both covered with a membrane. Bone thickness measurements clinically and tomographically were made before, immediately, and 6 months postoperatively. After 6 months, identical implants were placed in each grafted area, and primary stability was measured. Results: Eight patients with anterior horizontal bone defects were selected. Clinical outcomes at 6 months postgrafting in the autologous block revealed a mean thickness of 7.4 ± 1.6 mm, with an initial mean measurement of 3.4 ± 1.7 mm and 2.6% resorption, whereas the mean in the xenogeneic block was 8.9 ± 1.5 mm, 3.3 ± 1.6 mm, and 7.3%, respectively. Tomographic evaluation of the thickness at 6 months postgrafting in the autologous block was a mean 7.8 ± 1.8 mm, with an initial mean of 3.7 ± 1.6 mm and resorption of 0%, while the mean in the xenogeneic block was 9.3 ± 1.6 mm, 3.6 ± 1.4 mm, and 2.1%, respectively. No significant difference in bone thickness was observed immediately or 6 months after the procedure. The mean implant placement torque was 32 ± 22 Ncm in the autologous block and 18 ± 9 Ncm in the xenogeneic block (P = .004). Conclusion: Xenogeneic block was shown to be a suitable alternative to reconstruct horizontal defects in the alveolar ridge that had undergone extensive resorption, though lower insertion torques were obtained during implant placement.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help