LOGIN
 
Share Page:
Back

Volume 33 , Issue 1
January/February 2018

Pages 101–115


Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies

Fernando Bover-Ramos, DDS/José Viña-Almunia, DDS, PhD/Juan Cervera-Ballester, DDS/Miguel Peñarrocha-Diago, DDS, PhD, MD/Berta García-Mira, DDS, PhD


PMID: 28632253
DOI: 10.11607/jomi.5556

Purpose: The aim of this systematic review was to analyze the accuracy of implant placement using computer-guided surgery and to compare virtual treatment planning and outcome in relation to study type (in vitro, clinical, or cadaver). A further objective was to compare the accuracy of half-guided implant surgery with that of full-guided implant surgery. Materials and Methods: A PubMed search was performed to identify studies published between January 2005 and February 2015, searching the keywords “reliability AND dental implant planning” and “accuracy dental implant planning.” Inclusion criteria were established a priori. Horizontal coronal deviation, horizontal apical deviation, angular deviation, and vertical deviation were analyzed. Results: A total of 186 articles were reviewed, and 34 fulfilled the inclusion criteria. Information about 3,033 implants was analyzed in 8 in vitro studies (543 implants), 4 cadaver studies (246 implants), and 22 clinical studies (2,244 implants). Significantly less horizontal apical deviation and angular deviation were observed in in vitro studies compared to clinical and cadaver studies, but there were no statistically significant differences in apical coronal deviation or vertical deviation between the groups. Compared to half-guided surgery, full-guided implant surgery showed significantly less horizontal coronal deviation for cadaver studies, significantly less horizontal apical deviation for clinical studies, and significantly less angular deviation for both clinical and cadaver studies. Conclusion: Implant placement accuracy was lower in clinical and cadaver studies compared with in vitro studies, especially in terms of horizontal apical deviation and angular deviation. Full-guided implant surgery achieved greater accuracy than half-guided surgery.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2022 Quintessence Publishing Co, Inc JOMI Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Accepted Manuscripts
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help