Home Subscription Services
 
   

 
Oral Health and Preventive Dentistry
OHPD Home Page
About the Editor
Editorial Board
Submit
Author Guidelines
Submission Form
Reprints / Articles
Permissions
Advertising
MEDLINE Search
Offical Web Site
 
 
 
 
 
FacebookTwitter
Quintessence Publishing: Journals: OHPD

 

Oral Health & Preventive Dentistry

Edited by Anton Sculean, Poul Erik Petersen, Avijit Banerjee

ISSN (print) 1602-1622 • ISSN (online) 1757-9996

Publication:

2022
Volume 20 , Issue 1



Pages: 77–84
DOI: 10.3290/j.ohpd.b2805357
Back
Share Abstract:

A Comparative Assessment of Three Mandibular Retention Protocols: A Prospective Cohort Study

Jan Christian Danz / Isabella Scherer-Zehnder / Nikolaos Pandis

Purpose: Fixed retainers have been advocated for the prevention of anterior mandibular crowding after orthodontic treatment. However, limited data is available to help clinicians choose a retention protocol that is acceptable in terms of stability, emergencies, and side effects in the long term. It was the aim of this study to assess survival and alignment stability of the 0.016” x 0.022” stainless steel wire compared to more common protocols. Materials and Methods: Three different mandibular fixed retention protocols were compared in 600 consecutive patients: 1. 0.0215” multistrand wire (MW) with separate curing of resin and composite; 2. 0.016” x 0.022” stainless-steel wire with simultaneous curing of resin and composite (SS1C); and 3. 0.016” x 0.022” stainless-steel wire with separate curing of resin and composite (SS2C). The hazard rate for detachment across wire groups was assessed with a Cox frailty model. Results: Incisor alignment was maintained with all retention wires. One incisor with unexpected torque change was observed in group MW. The average annual emergency rate was below 2% for all three protocols. Fewer emergency visits were found in patients with solid steel wires than with multistrand wires. Detachment of the wire is the most common cause of emergency visits with no difference between wire types. Multistrand wires were more often damaged than were solid steel wires. There was no evidence that direct application of the composite on the uncured primer influenced retainer adhesion to the enamel. Conclusions: The mandibular anterior teeth can be predictably stabilised with a 0.016” x 0.022” stainless steel wire.

Full Text PDF File | Order Article

 

 
  © 2022 Quintessence Publishing Co Inc
 

Home | Subscription Services | Books | Journals | Multimedia | Events | Blog
Terms of Use | Privacy Policy | About Us | Contact Us | Advertising | Help | Sitemap | Catalog