LOGIN
 
Share Page:
Back

Volume 34 , Issue 3
May/June 2021

Pages 365–372


Relationship Between Internal Accuracy and Load-Bearing Capacity of Minimally Invasive Lithium Disilicate Occlusal Veneers

Nina Mörikofer, Med Dent/Goran I. Benic, PD Dr Med Dent/Ji-Man Park, DDS, MSD, PhD/Mutlu Özcan, Prof Dr Med Dent, PhD/Jürg Hüsler, Prof Em Dr Phil Nat/Alexis Ioannidis, Dr Med Dent


DOI: 10.11607/ijp.6735

Purpose: To test whether internal accuracy affects the load-bearing capacity of 0.5-mm–thick occlusal veneers made out of milled or heat-pressed lithium disilicate (LS2). Materials and Methods: Extracted human molars (N = 80) were divided into four groups (n = 20 each) depending on the bonding substrate (enamel [E] or dentin [D]) and the fabrication method (milling [CAD] or heat pressing [PRE]) for the occlusal LS2 veneers: (1) E-CAD; (2) D-CAD; (3) E-PRE; or (4) D-PRE. After restoration fabrication, the abutment teeth and the corresponding restorations were scanned and superimposed in order to measure the marginal and internal accuracy. After adhesive cementation, the specimens were thermomechanically aged and thereafter loaded until fracture. The load-bearing capacities (Fmax) were measured. Fmax and the marginal and internal accuracy between the groups were compared using Kruskal-Wallis test (P < .05) and pairwise group comparisons. In addition, the relationship between Fmax and the internal accuracy was analyzed using Spearman rank correlation. Results: Median Fmax values (and first and third quartiles) per group were as follows: 1,495 N (Q1: 932, Q3: 2,318) for E-CAD; 1,575 N (Q1: 1,314, Q3: 1,668) for E-PRE; 1,856 N (Q1: 1,555, Q3: 2,013) for D-CAD; and 1,877 N (Q1: 1,566, Q3: 2,131) for D-PRE. No statistical difference was found between the groups (P = .0981). Overall, the internal accuracy in the areas of the cusp (P < .0007) and fossae (P < .0001) showed significant differences. While no significant differences were detected in the marginal area (P = .3518), a significant correlation with a negative linear relationship was found between the 3D internal accuracy and the Fmax values (P = .0007). Conclusion: An increase in the internal accuracy raised the load-bearing capacity of minimally invasive LS2 occlusal veneers. In general, the restorations bonded to dentin in the occlusal regions showed a better accuracy compared to those bonded to enamel.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

IJP Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help