LOGIN
 
Share Page:
Back

Ahead of Print


A Randomized Clinical Trial comparing the clinical fit of CAD/CAM monolithic zirconia Fixed Dental Prostheses (FDP) on ti-base abutments based on digital or conventional impression techniques. One year follow-up.

Wiebe Derksen/Ali Tahmaseb/Daniel Wismeijer


DOI: 10.11607/ijp.7074

Purpose: To compare the fit and clinical performance of screw-retained monolithic zirconia implant fixed dental prostheses (FDPs) based on either intraoral optical scanning (IOS) or conventional impressions. Materials and Methods: Patients with two posterior tissue-level implants (Straumann Regular Neck) replacing two or three adjacent teeth were recruited. Impressions were taken with both IOS (True Definition Scanner, 3M ESPE) and a conventional (polyether) pick-up impression. Double-blind randomization was performed after impression-taking, and patients were to receive an FDP based on either the digital or the conventional impression. The fit was evaluated, and the time required for adjustments was recorded. Additionally, survival and technical complication rates with a follow-up of 1 year were documented. Results: A total of 38 patients requiring 45 FDPs were included: 24 FDPs in the test (IOS) and 21 in the control (conventional) group. The average adjustment time was 6.92 minutes (SD: 10.84, range: 0 to 49 minutes) for digital vs 12.38 minutes (SD: 14.52, range: 0 to 54 minutes) for conventional impressions (P = .090). A proper fit (no adjustments) was achieved in 33.3% of the digital and 28.6% of the conventional group. Forty-two FDPs could be placed within the two planned appointments, and 3 FDPs exhibited an unacceptable fit and required an extra appointment. Eight technical complications occurred during the first year of function. The overall restoration survival rate was 100%. Conclusion: The clinical fit of CAD/CAM FDPs based on digital impressions is comparable to conventional impressions. Screw-retained monolithic zirconia FDPs on Ti-base abutments show low major complication and survival rates in the short term.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

IJP Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help