Evaluation of the marginal fit of a CAD/CAM zirconia-based ceramic crown system

Mirza Rustum Baig BDS, MDS, FDSRCSEd, FDSRCPS, MRD/Yacoub Al-Tarakemah DDS, MS/Noor Hayaty Abu Kasim BDS, MSc, PhD/Ridwaan Omar BSc, BDS, MSc, FRACDS, FDSRCSEd


DOI: 10.11607/ijp.6654

Purpose: To evaluate the marginal fit of zirconia (Zi) CAD/CAM crowns in terms of gap and overhang compared to lithium disilicate (LDS) computer-aided design crowns, as well as the effect of finish line design on marginal accuracy. Materials and Methods: Stone dies were acquired from two master metal dies (n = 20 each) with two different finish lines and were scanned to produce digital models. Ceramic crowns (ZS-Ronde Zi, KaVo and IPS e.max CAD LDS, Ivoclar Vivadent) were designed and milled on the resulting 40 dies: 10 Zi-shoulder, 10 Zi-chamfer, 10 LDSshoulder, and 10 LDS-chamfer. Marginal gap and overhang were evaluated at six designated margin locations. The data were obtained, and the influence of material and finish line on the marginal fit of crowns was assessed using two-way analysis of variance and Bonferroni multiple comparisons test (α = .05). Results: Mean marginal gap and overhang on Zi crowns were 30 14 μm and 79 27 μm for the shoulder, respectively, and were 68 34 μm and 104 34 μm for the chamfer. The corresponding values for LDS crowns were 57 22 μm and 74 29 μm for the shoulder, and 62 12 μm and 59 27 μm for the chamfer. ANOVA revealed that the differences in marginal gap between the two materials were not significant (P > .05), but that the finish line effect and interaction were significant (P < .05). With regard to marginal overhang, significant differences were found between Zi and LDS crowns (P < .05), although the finish line geometries did not show any significant differences (P > .05). LDS crowns showed no differences between shoulder and chamfer margins for gap or overhang (P > .05), whereas significant differences were found in marginal gap between the Zi shoulder and chamfer margins (P < .005). Conclusion: In terms of marginal accuracy, shoulder margins produced smaller marginal gaps compared to chamfers for Zi CAD/CAM crowns.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

IJP Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help